3423: Johnson Controls Explains How to Cut Data Center Cooling Energy by 40%
In this episode of Tech Talks Daily, I’m joined by Todd Grabowski from Johnson Controls to unpack the physics, products, and design choices shaping the next generation of data center cooling. It’s a practical conversation that moves from chips and compressors to water, power, and land constraints, and what it really takes to keep modern infrastructure reliable at scale.
Todd brings three decades of experience to the table and a front-row view of how Johnson Controls and the York brand have kept their focus on energy efficiency, reliability, and sustainability for more than a century. That longevity matters when the market is moving fast. He explains why cooling now sits alongside power as the defining constraint for data centers, and why roughly forty percent of a facility’s energy can be spent on cooling rather than computation. If you lead technology, finance, or facilities, that single number should focus the mind.
Todd walks through Johnson Controls’ YVAM platform and the York magnetic bearing centrifugal compressor at its core, with real numbers on what that means in practice.
Consuming around forty percent less energy than typical cooling devices of the past five years and operating in ambient conditions up to fifty-five degrees Celsius, it is designed for the reality of hotter climates and denser loads. The naval pedigree of the driveline is a nice twist, since it was originally built for quiet and high-reliability conditions long before hyperscale data centers needed the same.
Sustainability threads through the entire discussion. Todd lays out how the company holds itself to internal targets while engineering solutions that reduce customer resource use. We talk about closed-loop designs that do not consume water, careful refrigerant choices with ultra-low global warming potential, and product footprints that consider carbon impact from the start. It is a useful reminder that sustainability is a systems problem, not a single feature on a spec sheet.
I was especially interested in the three resources Todd says every modern cooling strategy must balance. Land, because you need somewhere to reject heat. Power, because every watt pulled into cooling is a watt not used for compute. Water, because many regions are already under stress and consumption cannot be the answer. Good design weighs these factors against the climate, the workload profile, and the operational model, then standardizes wherever possible so the same unit can run efficiently in Scandinavia or Dubai without special tweaks.
We also dig into what AI means internally for Johnson Controls. It is showing up in manufacturing lines, speeding up design cycles, and improving the fidelity of compressor and heat transfer models. That translates into quicker time to market and more confidence in performance envelopes. On the market side, Todd is clear that demand has not softened. If anything, efficiencies tend to unlock more use cases, and the net effect is more workloads and continued pressure on facilities to cool them well.
If your team is wrestling with when to adopt liquid cooling, how to reduce PUE through smarter chiller choices, or how to plan for climate variability across a global footprint, this episode offers an honest, grounded view from someone who has shipped the hardware and lived with its trade-offs. It also doubles as a quiet celebration of engineering craft. The kind that rarely makes headlines, yet underpins everything we build in the AI age.
*********