Glaucoma, Vision & Longevity: Supplements & Science podcast

A New Glaucoma Laser Treatment Lowered Eye Pressure 31% — Beating Eye Drops in a Randomized Trial

0:00
27:34
Spol 15 sekunder tilbage
Spol 15 sekunder frem

This audio article is from VisualFieldTest.com.

Read the full article here: https://visualfieldtest.com/en/a-new-glaucoma-laser-treatment-lowered-eye-pressure-31-beating-eye-drops-in-a-randomized-trial

Test your visual field online: https://visualfieldtest.com

Support the show so new episodes keep coming: https://www.buzzsprout.com/2563091/support

Excerpt:

A New Glaucoma Laser Treatment Lowered Eye Pressure 31% — Beating Eye Drops in a Randomized Trial The headline is broadly accurate about one six-month comparison, but it needs context. In a new, single-center study, patients assigned to 360-degree MicroPulse laser trabeculoplasty had a larger average pressure reduction than patients assigned to stepped eye-drop therapy. But the laser group’s drops were deliberately tapered, while the comparison group’s medicines were maintained or increased. The study also did not compare MicroPulse treatment with selective laser trabeculoplasty, the better-established glaucoma laser. As of November 21, 2026, the study is promising early evidence—not proof that MicroPulse laser is better than selective laser trabeculoplasty, lasts for years, or can replace treatment for advanced glaucoma. The study was published on November 16, 2026. Source 1: 2026 randomized trial. () What the 90-patient trial studied The trial randomized 90 people, 45 to laser and 45 to medication. It was a six-month, prospective, parallel-group study at one hospital in China. The authors report that 142 people were screened and that 78 completed the full follow-up. The main analysis included all 90 randomized participants, with missing results handled by statistical imputation. Source 1: 2026 randomized trial. () Who was enrolled—and how severe was the disease? The paper’s table includes 11 people with ocular hypertension. Ocular hypertension means high eye pressure without established optic-nerve damage; it is not itself glaucoma. So, although the trial is described as a glaucoma study, not all 90 participants had glaucoma. For the full table, please open this article on visualfieldtest.com. The average visual-field mean deviation was about −4.8 decibels in the laser group and −4.7 decibels in the medication group. That suggests relatively mild visual-field loss on average, but the study does not report how many people had mild, moderate, or advanced glaucoma. Its results should therefore not be assumed to apply to people with advanced disease or very low pressure targets. Source 1: 2026 randomized trial. () Baseline pressure and medication use The reported average starting pressure was 24.2 millimeters of mercury in the MicroPulse group and 23.9 millimeters of mercury in the medication group. Participants were already using about 1.8 medicines per person in the laser group and 1.9 in the medication group. That is a relatively high average starting pressure. Laser studies often find larger pressure reductions in people who start with higher pressure, so these results may not predict the response of someone whose pressure is already in the mid-teens. Source 1: 2026 randomized trial. () Randomization and masking The article says an independent statistician generated the random sequence and that a central system concealed treatment assignment. The laser operator and treating doctors could not be masked to treatment. The people measuring pressure and reviewing imaging were reported to be masked to group assignment. Participants were asked not to reveal their treatment during visits, but they could not be unaware of whether they had received a laser or continued daily eye drops. The authors report that the study was registered in January 2026, before recruitment began. It was designed around a pressure outcome—not around long-term vision loss, rare safety events, or definitive comparisons between disease subtypes. Source 1: 2026 randomized trial. () What the laser treatment involved One experienced glaucoma specialist treated the full 360 degrees of the drainage angle using: 577-nanometer wavelength 300-micrometer spot size 1,000 milliwatts set power 15% duty cycle 0.5-millisecond “on” time and 2.83-millisecond “off” time 120 laser spots total—30 in each quadrant The procedure was performed through a contact lens used to view the drainage angle and took about 8 to 10 minutes. The paper does not report the time the laser remained on at each individual spot or the total energy delivered, so those details cannot be directly matched against laser settings in other studies. Source 1: 2026 randomized trial. () How medicines were handled The two groups followed different medication plans: MicroPulse group: Existing pressure-lowering drops were tapered and stopped during the first month, regardless of the early pressure response. Medicines could be restarted if pressure went above a patient-specific target. Medication group: Patients received stepped treatment, starting with a prostaglandin eye drop and adding other medicines if the target was not met. Treatment was generally maintained once the target was reached. The target was described as a 20% to 30% pressure reduction from baseline, or a level considered safe for the person’s glaucoma severity. Because targets were individualized and the treating doctors knew the treatment assignments, the study did not compare the laser and medicines under identical medication exposure. Source 1: 2026 randomized trial. () Visual-field, optical coherence tomography, and safety checks The study measured visual fields with a 24-2 automated field test at baseline and six months. It also measured the retinal nerve fiber layer and ganglion cell complex with optical coherence tomography at those visits. The average results were stable, with no meaningful difference between groups—but six months is too short to show whether a treatment slows glaucoma damage over time. Pressure was measured at clinic visits between 9 and 11 in the morning, using three readings from a non-contact tonometer. The paper says the instrument was checked against Goldmann applanation tonometry. This is useful for a consistent comparison, but it is not a full-day pressure profile. Source 1: 2026 randomized trial. () What happened to eye pressure at six months? For the full table, please open this article on visualfieldtest.com. The reported percentages are within-group reductions: MicroPulse: (24.2 − 16.8) ÷ 24.2 = 30.6% Medication: (23.9 − 18.7) ÷ 23.9 = 21.8% The reported 2.2-millimeter-of-mercury advantage is the difference between the groups’ average reductions: 7.4 minus 5.2. The trial’s repeated-measures statistical model gave a 95% confidence interval of 1.1 to 3.3 millimeters of mercury and a P value of 0.003. The raw average pressure at six months differed by 1.9 millimeters of mercury—16.8 versus 18.7—because the laser group started 0.3 higher. The difference in percent reduction was 8.8 percentage points. Source 1: 2026 randomized trial. () A 2.2-millimeter difference could matter clinically, especially if it helps someone reach their personal pressure target. But it is a modest average difference, and the trial did not show that MicroPulse treatment prevents more vision loss. The six-month visual-field and optic-nerve measurements were similar in both groups. The trial also reported that 82.2% of the laser group and 55.6% of the medication group reached at least a 20% pressure reduction; the percentages reaching at least 30% were 48.9% and 20.0%. Source 1: 2026 randomized trial. () The key interpretation issue: the laser group’s drops were intentionally withdrawn The trial’s pressure comparison is meaningful as a comparison of two treatment strategies: laser followed by a planned attempt to stop drops, versus continued or stepped-up drops. But it is not a clean test of laser versus drops at equal medication exposure. At six months, the laser group was using an average of 0.7 medicines, down from 1.8—a 61.1% decrease. Seventeen of 45 people (37.8%) were taking no pressure-lowering medicine at the six-month visit. The medication group averaged 1.8 medicines, compared with 1.9 at baseline. That medication reduction is relevant to patients who want to avoid daily drops. But the between-group difference is largely built into the protocol: the laser group’s medicines were deliberately tapered; the medication group’s were not. The authors correctly report medication burden descriptively rather than presenting it as an independent, formally tested treatment advantage. Source 1: 2026 randomized trial. () The 37.8% medication-free figure is therefore best understood as: this many people had no drops at month six after a protocol that stopped drops and restarted them when a pressure threshold was exceeded. It does not mean that 37.8% would have become medication-free under a fair comparison in which both groups were offered the same opportunity to taper. The quality-of-life results need similar caution. The questionnaire score improved more in the laser group, but patients knew whether they had received a laser or were still using drops. Avoiding daily medicine may genuinely make life easier; expectations and awareness of treatment can also influence a self-reported questionnaire. The study cannot separate those effects. Source 1: 2026 randomized trial. () Safety findings The laser group had three reported pressure spikes—6.7%—of more than 10 millimeters of mercury above baseline within 24 hours. They resolved by day three. Three participants had mild inflammation on the day after treatment, which resolved by one week. No serious adverse event or vision loss

Support the show

Flere episoder fra "Glaucoma, Vision & Longevity: Supplements & Science"